Single-person L-shaped Suspended Working Platform
Single-person L-shaped Suspended Working Platform is a temporary access configuration for facade construction, cleaning, painting or maintenance where a roof-suspended system is appropriate. The existing specification references ZLP250, ZLP500, ZLP630, ZLP800, ZLP1000, 250kg, 50HZ, 60HZ. These values should be confirmed against the final supplied configuration and destination power supply.

L storkróp Ál 250kg Stórhúðað Platform
Það eru 3 tegundir í boði fyrir hverja tegund af Evrópu vörumerkinu. Þeir eru stál máluð, heitt galvaniseruðu, ál.


| Eignarleyfi nr. | ZLP250 | ZLP500 | ZLP630 | ZLP800 | ZLP1000 | |
| Álagsþyngd (kg) | 250 | 500 | 630 | 800 | 1000 | |
| Lyftihraði (m / mín) | 9 ~ 11 | 9 ~ 11 | 9 ~ 11 | 8 ~ 10 | 8~10 | |
| Mótorafl (kw) | 1 × 1,5 50Hz / 60Hz | 2 × 1,5 50Hz / 60Hz | 2 × 1,5 50Hz / 60Hz | 2 × 1.8 50HZ / 60HZ | 2 × 2,2 50HZ / 60HZ | |
| Brake veltingur (Km) | 16 | 16 | 16 | 16 | 16 | |
| Stillingarmörk hornshorða (°) | 3 ° - 8 ° | 3 ° - 8 ° | 3 ° - 8 ° | 3 ° - 8 ° | 3 ° - 8 ° | |
| Fjarlægð milli tveggja stáltappa (mm) | ≤100 | ≤100 | ≤100 | ≤100 | ≤100 | |
| Metið teygja framhljóms (mm) | 1500 | 1500 | 1500 | 1500 | 1500 | |
| Upphæð vettvangs | Læsa | Ál | Ál | Ál | Ál | Ál |
| Nr.Of pallur rekki | Single rekki | Single rekki | Single rekki | Single rekki | Single rekki | |
| Nr.Of pallur | 1 | 2 | 3 | 3 | 3 | |
| L × W × H (mm) | 1200 × 690 × 1300 | (2500 × 2) × 690 × 1300 | (2000 × 3) × 690 × 1300 | (2500 × 3) × 690 × 1300 | (2500 × 3) × 690 × 1300 | |
| Þyngd (kg) | 84 kg | 350 kg | 375 kg | 410 kg | 455kg | |
| Stöðvunarbúnaður (kg) | 175 kg | 2 × 175 Kg | 2 × 175 Kg | 2 × 175 Kg | 2 × 175 Kg | |
| Mótvægi (kg) valfrjálst | 25 * 20 stk | 25 × 30 stk | 25 × 36 stk | 25 × 40 stk | 25 × 44 stk | |
| Þvermál reipi úr stáli (mm) | 8.3 | 8.3 | 8.3 | 8.6 / 9.1 | 8.6 / 9.1 | |
| Max Lyftihæð (m) | 300 | 300 | 300 | 300 | 300 | |
| Snúningshraði hreyfils (r / mín) | 1420 | 1420 | 1420 | 1420 | 1420 | |
| Spenna (v) 3PHASES | 220V / 380V / 415V | 220V / 380V / 415V | 220V / 380V / 415V | 220V / 380V / 415V | 220V / 380V / 415V | |
Configuration and Applications
Model selection should consider the complete working load, platform section arrangement, building height, facade geometry and operating environment. A higher model rating does not allow the platform length or carried load to exceed the approved system limits.
Project Information Required
- Building height and required working length
- Workers, tools and material load
- Voltage, phase and frequency
- Roof parapet, suspension beam and counterweight conditions
Review our frestað vinnuvettvangur, browse the product article library, or send the project requirements to Shanghai Success Construction International Trade Co., Ltd. Site planning should follow applicable local regulations and the OSHA suspended scaffold requirements.